20% OFF shipping at sharerebate.net on orders over $79 + up to 10% OFF products
sharerebate.net
home > Wilkins 2-950XLTDABFSS | Double Check Detector Backflow Assembly, 2 Inches > Wilkins 2-950XLTDABFSS | Double Check Detector Backflow Assembly, 2 Inches
download picture
Wilkins 2-950XLTDABFSS | Double Check Detector Backflow Assembly, 2 InchesNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 2 950XLTDABFSS is a Double Check Detector Backflow Preventer Assembly designed to protect potable water in fire sprinkler systems from backsiphonage and backpressure. Key Specifications: Size: 2 Inches Maximum Working Water Pressure: 175 PSI Maximum Working Water Temperature: 180F Notable Certifications: ASSE 1048, UL, C UL Classified
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 2-950XLTDABFSS is a Double Check Detector Backflow Preventer Assembly designed to protect potable water in fire sprinkler systems from backsiphonage and backpressure.

 

Key Specifications:

  • Size: 2 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1048, UL, C-UL Classified
  • End Connections: FNPT, ANSI B1.20.1

 

Other Related Variants:

  • 2-950XLTDABFSSLM: Less meter version

 

Materials:

  • Main valve body: Cast Bronze ASTM B 584
  • Access covers: Cast Bronze ASTM B 584
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers: Silicone (FDA approved)
  • Elastomers: Buna Nitrile (FDA approved)
  • Polymers: Noryl™, NSF Listed
  • Springs: Stainless Steel, 300 series
  • Test cock cover: Plastic

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 Inches and a maximum of 30 Inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Suitable for horizontal or vertical orientation.

 

Standards Compliance:

ASSE Listed 1048; UL Classified (horizontal & vertical); C-UL Classified (horizontal & vertical); AWWA Compliant C510; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 & 372 (lead-free)

 

Features & Benefits:

  • Dual Protection: Protects potable water from both backsiphonage and backpressure of polluted water in fire sprinkler systems.
  • Leak Detection: Incorporates metered bypass to detect leaks and unauthorized water use for enhanced system monitoring.
  • Supervisory Monitoring: Butterfly valve supervisory switches (SS option) provide remote indication of valve position and circuit status for fire alarm systems, UL and FM approved for indoor and outdoor use.
  • Easy Maintenance: First and second check valves located at 45° angle and accessible from the top without removing device from line; test cock plugs protect ports from debris.

 

FAQ

 

Q: Can the Zurn 2-950XLTDABFSS be installed in both horizontal and vertical orientations?

A: Yes, the Zurn 2-950XLTDABFSS is approved for both horizontal and vertical installation per ASSE 1048, UL, and C-UL classifications.

Q: What is the purpose of the butterfly valve supervisory switches on this model?

A: The SS suffix indicates butterfly valve supervisory switches that are UL and FM approved, providing remote indication of valve position and circuit status for integration with fire alarm systems.

Q: Where should the Wilkins 2-950XLTDABFSS be installed?

A: Install on potable water connections in fire sprinkler systems where low health hazard backflow protection with supervisory monitoring is required, mounted 12 to 30 Inches above adequate drains.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 2-950XLTDABFSS | Double Check Detector Backflow Assembly, 2 Inches

Item no : 16756972158
sold recently : Login >>
US$ 2097.99
Pay in 4 interest-free payments of $524.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 2097.99

1-11

US$ 1888.19

12-35

US$ 1468.59

36-59

US$ 1258.79

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches