20% OFF shipping at sharerebate.net on orders over $79 + up to 10% OFF products
sharerebate.net
home > Wilkins 114-500XL | Water Pressure Reducing Valve with Integral By-pass Check > Wilkins 114-500XL | Water Pressure Reducing Valve with Integral By-pass Check
download picture
Wilkins 114-500XL | Water Pressure Reducing Valve with Integral By-pass CheckThe Wilkins 114 500XL is a water pressure reducing valve with integral by pass check valve, designed for industrial and commercial water systems requiring reliable pressure control. Key Specifications: Size: 1 1 4 Inches Maximum Working Water Pressure: 300 psi Maximum Working Water Temperature: 140F Notable Certifications: ASSE 1003, cUPC, CSA B356 Threaded connections (FNPT): ANSI B1. 20. 1 Other Related Variants: 112 500XL: 1 1 2 Inches model size 1
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

The Wilkins 114-500XL is a water pressure reducing valve with integral by-pass check valve, designed for industrial and commercial water systems requiring reliable pressure control.

 

Key Specifications:

  • Size: 1 1/4 Inches
  • Maximum Working Water Pressure: 300 psi
  • Maximum Working Water Temperature: 140°F
  • Notable Certifications: ASSE 1003, cUPC, CSA B356
  • Threaded connections (FNPT): ANSI B1.20.1

 

Other Related Variants:

  • 112-500XL: 1 1/2 Inches model size
  • 1-500XL: 1 Inch model size
  • 212-500XL: 2 1/2 Inches model size
  • 3-500XL: 3 Inches model size
  • 12-500XL: 1/2 Inch model size
  • 34-500XL: 3/4 Inches model size

 

Materials:

  • Main valve body: Low Lead Cast bronze ASTM B 584
  • Access covers: Low Lead Cast bronze ASTM B 584 / Low Lead Brass
  • Fasteners: Stainless steel, 300 series
  • Stem & plunger: Low Lead Cast bronze ASTM B 584 / Low Lead Brass
  • Elastomers: Buna Nitrile (FDA approved) / EPDM (FDA approved)
  • Cap gaskets: Natural vulcanized fibre / Acetal (Delrin™ 500)
  • Springs: Oil tempered wire, ASTM A 229
  • Seat: Stainless steel, 300 series

 

Typical Installation:

Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Zurn 114-500XL may be installed in any position. If installed in a pit, vault, or inside application, specify the "SC" sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 3 to 1 (i.e.: 150 psi inlet reduced to 50 psi outlet). Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting.

 

Standards Compliance:

ASSE Listed 1003; cUPC Listed; CSA Certified B356; City of Los Angeles Approved; NSF/ANSI/CAN 61 and 372

 

Features & Benefits:

  • High Flow Capacity: Ideal for industrial water lines and commercial water systems with balanced piston design for smooth, responsive operation.
  • Integral By-pass Check Valve: Prevents buildup of excessive system pressure caused by thermal expansion, providing comprehensive pressure control.
  • Low Lead Compliance: Meets NSF/ANSI/CAN 61 and 372 standards with less than 0.25% weighted average lead content for safe potable water applications.
  • Flexible Installation: Can be installed in any position with single union connection for easy maintenance without removing body from line.

 

FAQ

 

Q: What is the factory preset pressure for the Wilkins 114-500XL?

A: The Wilkins 114-500XL comes factory preset at 50 psi with an adjustable reduced pressure range of 25 psi to 75 psi.

Q: Can this valve be installed in any orientation?

A: Yes, the Model 500XL may be installed in any position. However, if installed in a pit, vault, or inside application, the "SC" sealed cage option should be specified.

Q: What is the maximum recommended pressure reduction ratio?

A: Multiple installations are recommended where the desired pressure reduction is more than 3 to 1 (for example: 150 psi inlet reduced to 50 psi outlet) to ensure optimal performance.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 114-500XL | Water Pressure Reducing Valve with Integral By-pass Check

Item no : 52592038150
sold recently : Login >>
US$ 510.98
Pay in 4 interest-free payments of $127.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 510.98

1-11

US$ 459.88

12-35

US$ 357.69

36-59

US$ 306.59

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches