G-Shock GW9500-1 MudmanG SHOCK Mudman, a timepiece designed to thrive on tough, rough, and outdoor use. The G Shock Master of G line of watches was developed with the intention to withstand the harshest environments. This MUDMAN model GW9500 1D has been designed with the triple sensor, with this new take on the tradition MUDMAN this has been made with a slimmer and compact design, allowing ease of use and functionality when taking on tough and rugged adventures. Bio based
Shopping security
Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
product description
Why choose thelockerguy wholesale?
G-SHOCK Mudman, a timepiece designed to thrive on tough, rough, and outdoor use. The G-Shock Master of G line of watches was developed with the intention to withstand the harshest environments. This MUDMAN model GW9500-1D has been designed with the triple-sensor, with this new take on the tradition MUDMAN this has been made with a slimmer and compact design, allowing ease of use and functionality when taking on tough and rugged adventures.
- Bio-based Resin Band
- Bio-based Resin Case
- Shock Resistant
- Mud Resistant
- Carbon Core Guard Structure
- Mineral Glass
- 200 Meter Water Resistance
- 56.7 x 52.7 x 14.8mm Case Size
- Tough Solar (Solar Powered)
Sensor feature:
- Digital compass
- Measures and displays direction as one of 16 points.
- Measuring range: 0 to 359°
- Measuring unit: 1°
- 60 seconds continuous measurement
- Graphic direction pointer
- Bidirectional calibration
- Magnetic declination correction
- Bearing memory
- Altimeter
- Measuring range: -700 to 10,000 m (-2,300 to 32,800 ft.)
- Measuring unit: 1 m (5 ft.)
- Manual memory measurements (up to 30 records, each including altitude, date, time)
- Auto log data (High/low altitudes, auto cumulative ascent, and descent)
- Trek log data (up to 14 records of high/low altitudes, auto cumulative ascent, and descent of treks)
- Others: Relative altitude readings (-3,000 to 3,000 m),
- Selectable measurement interval: 5 seconds or 2 minutes
- *1 second for first 3 minutes only
- *Changeover between meters (m) and feet (ft)
- Barometer
- Display range: 260 to 1,100 hPa (7.65 to 32.45 in Hg)
- Display unit: 1 hPa (0.05 inHg)
- Atmospheric pressure tendency graph (Past 42 hours of readings)
- Atmospheric pressure differential graphic
- Barometric pressure tendency information alarm
- *Changeover between hPa and in Hg
- Thermometer
- Display range: -10 to 60℃ (14 to 140℉)
- Display unit: 0.1℃ (0.2℉)
- *Changeover between Celsius (℃) and Fahrenheit (℉)